Type |
Unit |
Heracell 150i |
Dimensions |
Internal Volume: |
l |
150 (5.3 cu.ft.) |
External (w x h x d) |
mm |
637 x 867 x 782 |
|
inch |
25.1 x 34.1 x 30.8 |
Internal (w x h x d) |
mm |
470 x 607 x 530 |
|
inch |
18.5 x 23.9 x 20.9 |
Weight (excl. accessories) |
kg |
70 |
|
lbs. |
154 |
Shelves |
Shelves full width (w x d) |
mm |
423 x 465 |
|
inch |
16.7 x 18.3 |
No. of shelves standard/maximum |
no. |
3/10 |
Max. load per shelf/total load |
kg |
10/30 |
|
lbs. |
22/66 |
Material |
Interior chamber |
stainless steel/solid copper |
stainless steel/solid copper |
Shelves, fan impeller |
stainless steel/solid copper |
stainless steel/solid copper |
ContraCon decontamination routine |
verified by accredited laboratories |
verified by accredited laboratories |
Decontamination phase, on all surfaces |
90/9 |
90/9 |
Period (ambient temperature 20°C) |
25 |
25 |
Temperature |
|
air jacket temperature control |
Temperature control range |
°C |
TA1 +3 … 55 |
Temperature deviation, time2/spatial2 |
K |
± 0.1/± 0.5 |
Ambient temperature range |
°C |
+18 … 33 |
Period (ambient temperature 20°C) |
25 |
25 |
Humidity |
Constant humidity3 |
%rH |
95 ± 3 |
Fill amount/water quality |
l |
max. 3
distilled/autoclaved and demineralized |
CO2 |
Measure and control range |
Vol – % |
0 … 20 |
Control accuracy |
Vol – % |
± 0.1 |
Inlet pressure |
bar |
0.8 … max. 1 |
Gas purity |
% |
99.5, medical quality min. |
O2 |
Measure and control range |
Vol – % |
1..21 / 5..90 |
Control accuracy |
Vol – % |
± 0.2 |
Inlet pressure |
bar |
0.8… max. 1 |
Gas purity |
% |
99.5; medical quality min. |
Electrical Data |
Rated voltage |
V |
1/N/PE AC; 230 (120) |
Rated output |
kW |
0.58 (0.62) |
Rated frequency |
Hz |
50/60 |
Heat emission to environment
at 37°C |
kWh/h |
0.06 |
with ContraCon |
kWh/h |
0.11 |