본문 바로가기 주메뉴 바로가기

Evolution 260 Bio UV-Visible Spectrophotometer (Evolution 260)

Evolution 260 Bio UV-Visible Spectrophotometer

주요특징

  • Nucleic Acid concentration by direct UV measurement at 260nm including DNA, ssDNA, RNA, and siRNA
  • Nucleic acid purity measurements from 260/280nm and 260/230 ratios
  • Protein analysis by direct UV measurement at 205 or 280nm
  • Most common colorimetric analysis methods including: Pierce 660nm Protein assay, Bradford, BCA and Lowry
  • Measuring the fluorescence labeling efficiency for proteins and nucleic acids
  • Measuring the microarray labeling efficiency with one or two dyes
  • Personalize your home screen for easy navigation and convenience
  • Workbook tools save time and ensure accurate results
  • CUE scripting allows creation of customized interface and simplified workflow
  • Double-beam geometry ideal for kinetics or any sample that may change over time
  • Application Focused Beam Geometry (AFBG) technology provides superior results for microcells and turbid samples
  • Xenon flash lamp requires no warm-up time allowing instant measurements
  • Electronic triggering provides the highest level of accuracy for rapid-mixing kinetics measurements
  • Precision monochromator drive delivers fast scanning data collection and wavelength accuracy Powerful Convenience at your Fingertips
  • Color, touch screen provides instrument control using built-in computer
  • Integrated keypad allows communication with INSIGHT software
  • Choice of Local or PC configurations provides flexibility and convenience

안내사항

   현재 홈페이지에 등록된 제품들은 재고 유무와 관계없이 구입이 가능하며, 별도문의의 상품인 경우 반드시 유선상 확인 후 구매부탁드립니다.
   납기가 표기된 상품의 경우 일반적인 수입진행에 소요되는 기간이며, 상품에 따라 납기일정이 추가 될 수 있으니 참고부탁드립니다.



Thermo Scientific™ Evolution™ 260 Bio UV-Visible Spectrophotometer

 

 

Description

Advance your research with reliable, absorbance results from the Thermo Scientific™ Evolution™ 260 Bio UV-Vis spectrophotometer, designed for the changing field of life science. With the choice of tablet or computer control, the Evolution 260 Bio spectrophotometer offers high-performance measurements for a variety of biological samples and measurements. Powerful software, precision optics, and an extensive line of accessories combine for a complete solution to move you from samples to answers faster. Thermo Scientific™ INSIGHT™ software, included with the Evolution 260 Bio system, offers pre-programmed assay methods for increased accuracy and convenience.

 

Complete Life Science Applications
Next generation INSIGHT software provides the streamlined convenience of easy-to-understand nucleic acid and protein analysis methods and includes dedicated modules for:
· Nucleic Acid concentration by direct UV measurement at 260nm including DNA, ssDNA, RNA, and siRNA
· Nucleic acid purity measurements from 260/280nm and 260/230 ratios
· Protein analysis by direct UV measurement at 205 or 280nm
· Most common colorimetric analysis methods including: Pierce 660nm Protein assay, Bradford, BCA and Lowry
· Measuring the fluorescence labeling efficiency for proteins and nucleic acids
· Measuring the microarray labeling efficiency with one or two dyes

 

Customizable, Straightforward INSIGHT Software
·
Personalize your home screen for easy navigation and convenience
· Workbook tools save time and ensure accurate results
· CUE scripting allows creation of customized interface and simplified workflow

 

Best-in-Class Performance
·
Double-beam geometry ideal for kinetics or any sample that may change over time
· Application Focused Beam Geometry (AFBG) technology provides superior results for microcells and turbid samples
· Xenon flash lamp requires no warm-up time allowing instant measurements
· Electronic triggering provides the highest level of accuracy for rapid-mixing kinetics measurements
· Precision monochromator drive delivers fast scanning data collection and wavelength accuracy Powerful Convenience at your Fingertips
· Color, touch screen provides instrument control using built-in computer
· Integrated keypad allows communication with INSIGHT software
· Choice of Local or PC configurations provides flexibility and convenience

 

Accessories for all your Sampling Needs
·
Wide accessory selection with various temperature control options, sample changers, sippers and solid sampling devices complete your analysis
· Automated cell changers with Peltier temperature control increase sample throughput
· Choice of Peltier Single Cell Holder or a Smart 8-Cell Peltier system for temperature control and sample monitoring from 0° to 100°C
· Easy software integration gives you complete control of your measurements

 

Reliable Assurance of System Performance
·
The Thermo Scientific UV Validator package provides support for system qualification and validation activities
· Complete documentation facilitates compliance of your system with the requirements of FDA, GxP, ISO 9001:2000 and ISPE 2001 guidelines and regulations
· CVC and Mercury Lamp accessory automated testing ensures accuracy of your data
· Thermo Scientific INSIGHTsecurity software provides complete tools to meet 21 CFR Part 11 requirements

 


Specifications

Accuracy (Photometric) 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST
Beam Geometry Double-beam with Application Focused Beam Geometry
Data Interval 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
Dimensions (L x W x H) 62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Optical Design Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Drift <0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up
Noise 0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Photometric Accuracy Instrument 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST
Photometric Range >3.5A
Scan Ordinate Modes Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Baseline Flatness ±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Certifications/Compliance ISO 9001:2008
Detector Type Dual Silicon Photodiodes
Lamp Xenon Flash Lamp, 3-year warranty (7 years typical lifetime)
Spectral Bandwidth Variable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Electrical Requirements 100-240 V 50-60 Hz selected automatically, 150W maximum
Pharmacopoeia Compliance Testing (Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display -0.3 - 4.0A
Photometric Repeatability ±0.0002A
Scan Speed <1-6000nm/min, variable
Wavelength Accuracy ±0.5nm (541.9, 546.1nm mercury lines) ±0.8nm (full range 190-1100nm)

  • 배송 안내

    택배 배송을 기본으로 하며 고객님의 요청에 의해 화물로 배송이 가능합니다.
    고객님의 요청에 의한 긴급 배송(고속버스 화물, 퀵서비스 등)으로 인한 물류비용은 고객님의 부담입니다.
    제품 설치 및 교육이 필요한 경우는 Off-Line으로 본사 기술부와 미리 논의 하시고, 직납 일정등의 협의를 부탁드립니다.

  • 배송 기간

    재고가 있는 품목에 한하여 입금 확인 후 2일 이내에 발송 됩니다. (입금 확인은 당일 3시 마감되며, 3시 이후 입금 건은 익일 처리 됩니다.)
    택배의 경우 일반적으로 발송일로부터 3~7일, 도서/산간/오지 등 교통이 불편한 지역의 경우 4~8일(토.일, 공휴일 제외) 정도 소요됩니다.

    불가 항력의 사유(일시품절/제조사로부터의 제품 수급 문제/천재지변 등)로 배송이 지연 될 경우 고객님께 연락을 드리겠습니다.
    수입품목의 공급 및 재고 상태는 주문시점에 따라 달라질 수 있으며, 공급이 어려울 경우 주문접수 후 주문이 취소 될 수 있습니다.
    재고가 없는 상품의 경우 상품이 입고 된 이후 발송이 가능하므로, 안내 받으신 배송기간 보다 다소 연장될 수 있습니다.
    제품 준비 과정에 차질이 생겨 늦어질 경우에는 고객님께 연락을 드리겠습니다.
    주문하신 상품은 결제 확인 후 발송됩니다.
    결제 후 메일 [ scist@scist.co.kr ]이나 전화 [ 031-546-8799 ]으로 연락 주시면 더욱 빨리 처리 해 드리겠습니다.

  • 배송 지역

    전국 어느 지역이나 배송 가능합니다. (단, 지역에 따라서 배송기간에 다소 차이가 있을 수 있습니다.)

  • 배송 운임

    주문 금액 기준 (부가세 별도) 총액 10만원 이상 주문시에는 무료로 배송해 드립니다. (택배기준)
    단, 10만원 미만 주문 시 착불 발송되며, 요청에 따라 주문자 사전 결제로 선불 배송 가능합니다.
    택배 배송이 불가능한 상품(장비 류 등)이나, ‘운임비 별도’로 명시 된 상품, 고객요청에 의한 운동수단 이용 시 배송비는 주문자 부담으로 진행됨에 유의 해 주시기 바랍니다.

  • 배송 확인 방법

    마이페이지의 주문/배송조회 내역에서 확인 가능합니다.

  • 교환 및 반품 안내

    상품에 하자가 있거나 주문한 상품과 다를 경우, 수령일로부터 15일 이내인 경우에 한하여 1:1 상품교환 또는 전액 환불 조치 해드리며,
    이에 소요되는 모든 비용 또한 싸이스트(주)에서 부담합니다.
    제품에 하자는 없지만, 다른 상품으로 교환하거나 반품하고자 할 경우, 수령일로 부터 7일 이내이며 미개봉 제품인 경우에 한하여 조치해 드립니다.
    이에 소요되는 비용은 고객님 부담입니다. (제품 사용 후 변심에 의한 교환 및 환불은 불가)
    제품의 교환 및 반품 시에는 상품 비닐 및 박스(Brand Box)를 수령하신 상태 그대로 보존하고 있을 경우에만 가능합니다.
    교환 및 반품 택배 보내실 때 상품 박스(Brand Box)가 손상되지 않도록 반드시 외부에 박스 한 겹 더 포장 부탁드립니다.

    * 건전지가 포함된 제품의 경우 수입 및 유통 과정에서 건전지의 전압 저하 및 방전의 경우가 있을 수 있습니다. 이럴 경우 영업 담당자에게 연락 주시면 신속하게 처리해 드리도록 하겠습니다.

  • 교환 및 반품, 환불이 불가능 한 경우

    1. 이용자에게 책임이 있는 사유로 제품이 훼손된 경우
    2. 이용자의 사용 또는 일부 소비에 의하여 재화 등의 가치가 현저히 감소한 경우
    3. 제품의 포장(비닐 및 상품박스)을 훼손 한 경우
    4. 주문 당시 재고가 없어서 국내 / 해외 조달 분 중 수입 발주 되어진 상품
    * 재고 상품이 아닌 경우, 수입 발주 되어진 상품의 주문 취소도 불가

  • 환불 안내

    현금 결제의 경우 구매자의 이름(또는 회사명)으로 개설된 은행계좌로 송금되며, 카드 결제의 경우 카드 승인 취소로 조치 해 드립니다.

Quick Menu