Thermo Scientific™ Evolution™ 260 Bio UV-Visible Spectrophotometer 
 
 
Description  
Advance your research with reliable, absorbance results from the Thermo Scientific™ Evolution™ 260 Bio UV-Vis spectrophotometer, designed for the changing field of life science. With the choice of tablet or computer control, the Evolution 260 Bio spectrophotometer offers high-performance measurements for a variety of biological samples and measurements. Powerful software, precision optics, and an extensive line of accessories combine for a complete solution to move you from samples to answers faster. Thermo Scientific™ INSIGHT™ software, included with the Evolution 260 Bio system, offers pre-programmed assay methods for increased accuracy and convenience.
 
Complete Life Science Applications
Next generation INSIGHT software provides the streamlined convenience of easy-to-understand nucleic acid and protein analysis methods and includes dedicated modules for:
· Nucleic Acid concentration by direct UV measurement at 260nm including DNA, ssDNA, RNA, and siRNA
·  Nucleic acid purity measurements from 260/280nm and 260/230 ratios
·  Protein analysis by direct UV measurement at 205 or 280nm
·  Most common colorimetric analysis methods including: Pierce 660nm Protein assay, Bradford, BCA and Lowry
·  Measuring the fluorescence labeling efficiency for proteins and nucleic acids
·  Measuring the microarray labeling efficiency with one or two dyes
 
Customizable, Straightforward INSIGHT Software
· Personalize your home screen for easy navigation and convenience
· Workbook tools save time and ensure accurate results
·  CUE scripting allows creation of customized interface and simplified workflow
 
Best-in-Class Performance
· Double-beam geometry ideal for kinetics or any sample that may change over time
·  Application Focused Beam Geometry (AFBG) technology provides superior results for microcells and turbid samples
·  Xenon flash lamp requires no warm-up time allowing instant measurements
·  Electronic triggering provides the highest level of accuracy for rapid-mixing kinetics measurements
·  Precision monochromator drive delivers fast scanning data collection and wavelength accuracy Powerful Convenience at your Fingertips
·  Color, touch screen provides instrument control using built-in computer
·  Integrated keypad allows communication with INSIGHT software
·  Choice of Local or PC configurations provides flexibility and convenience
 
Accessories for all your Sampling Needs
· Wide accessory selection with various temperature control options, sample changers, sippers and solid sampling devices complete your analysis
·  Automated cell changers with Peltier temperature control increase sample throughput
·  Choice of Peltier Single Cell Holder or a Smart 8-Cell Peltier system for temperature control and sample monitoring from 0° to 100°C
·  Easy software integration gives you complete control of your measurements
 
Reliable Assurance of System Performance
· The Thermo Scientific UV Validator package provides support for system qualification and validation activities
·  Complete documentation facilitates compliance of your system with the requirements of FDA, GxP, ISO 9001:2000 and ISPE 2001 guidelines and regulations
·  CVC and Mercury Lamp accessory automated testing ensures accuracy of your data
·  Thermo Scientific INSIGHTsecurity software provides complete tools to meet 21 CFR Part 11 requirements
 
 Specifications
  
    
      |  | 
    
      | Accuracy (Photometric) | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST | 
    
      | Beam Geometry | Double-beam with Application Focused Beam Geometry | 
    
      | Data Interval | 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm | 
    
      | Dimensions (L x W x H) | 62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in) | 
    
      | Optical Design | Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator | 
    
      | Drift | <0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up | 
    
      | Noise | 0A: <0.00015A 1A: <0.00025A
 2A: <0.00080A
 260nm, 1.0nm SBW, RMS
 | 
    
      | Photometric Accuracy Instrument | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST | 
    
      | Photometric Range | >3.5A | 
    
      | Scan Ordinate Modes | Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity | 
    
      | Baseline Flatness | ±0.0010A, 200-800nm, 1.0nm SBW, smoothing | 
    
      | Certifications/Compliance | ISO 9001:2008 | 
    
      | Detector Type | Dual Silicon Photodiodes | 
    
      | Lamp | Xenon Flash Lamp, 3-year warranty (7 years typical lifetime) | 
    
      | Spectral Bandwidth | Variable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized | 
    
      | Electrical Requirements | 100-240 V 50-60 Hz selected automatically, 150W maximum | 
    
      | Pharmacopoeia Compliance Testing | (Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line | 
    
      | Photometric Display | -0.3 - 4.0A | 
    
      | Photometric Repeatability | ±0.0002A | 
    
      | Scan Speed | <1-6000nm/min, variable | 
    
      | Wavelength Accuracy | ±0.5nm (541.9, 546.1nm mercury lines) ±0.8nm (full range 190-1100nm) |